Skip to main content

Maintaining SF6 Gas Quality for GIS & Circuit Breaker

Maintaining SF6 gas quality for GIS and Circuit Breaker is a must. Any issue in insulation medium for High Voltage equipment is a time bomb. Dew point of SF6 gas should be periodically measured, if it's found below accepted limit during routine maintenance, SF6 gas recovery process should be performed in order to improve the gas quality. Сircuit breakers with vacuum champer are often confused with SF-6. They have a different arc extinguishing technology.

Maintaining SF6 gas quality

FTHS Series of FUOOTECH Company SF6 Gas handling system is applied to the extraction, filling, backfilling, purification and recovery of sulfur hexafluoride gas in SF6 electrical equipment. The built-in filtration and adsorption system can absorb impurities, water, decomposition products and oil content in SF6 gas. The integrated design and small size are easy to move and use. The efficient maintenance - free filtration system greatly guarantees the quality of SF6 gas recovery. SF6 gas should be recycled when the SF6 electrical equipment is applied.

Therefore, FTHS Series SF6 Gas Recovery and Re-filling Machine is a special designed to recover and fill SF6 gas when making and maintaining sf6 electrical equipment. SF6 gas recovery device is suitable for the extraction, filling, backfilling, purification and recovery of sulfur hexafluoride gas in sf6 electrical equipment.



The recycled SF6 gas can be directly stored into the container in a liquid form, small volume, easy to move, fast vacuum extraction speed, the recovered SF6 gas can be dried and filtered. It can also be backfilled with SF6 gas to SF6 electrical equipment.

Main Features


  1. Advanced design, full function and compact structure with simple operation.
  2. Compressed systems: it takes closed compressor to ensure no leakage.
  3. Vacuum systems: it takes rotary vane vacuum pump to prevent oil returning
  4. Purification systems: Equipped with Ingersoll Rand filters which takes electric heating and high efficient adsorbents. Without frequent replacement of the adsorbents, so the purification result is better.
  5. Electric systems: Equipped with automatically confirmation three phase power devices, failure protection.
  6. Control systems: the valves take the latest technology.
  7. Storage system: Provide the storage tank according to users requirements.

Comments

Popular posts from this blog

How Forklift Fleet Management Systems Can Bring Flexibility & Agility to Your Supply Chain

Important lesson that has risen to the top is the precarious balance between supply and demand and the potential danger of having a supply chain that is too lean. While there are benefits to a lean approach, the pandemic has shown the limitations that could occur as many supply chains were caught off-guard, lacking the flexibility and agility to quickly react to changing market demands and conditions. Many companies struggled to get their supply chains back on track, with some still confronting challenges as we entered the holiday shipping season. There are a number of strategic steps you can take to enhance your supply chain with greater flexibility and agility. When it comes to your material handling equipment needs, the best step you can take is implementing a forklift fleet and operator management system. When utilized effectively, the right system can guide and inform an approach that increases flexibility and agility while helping maintain lean principles and identifying o...

Circuit Breakers Breaking Capability - Right Calculating According to Existing Operational Model

Each circuit breaker has its own name plate, we shall find auto recloser sequence, O-C-O with time sequences, for distribution systems auto recloser may have two trials, auto recloser is leading into chock of power system but improves system reliability up to the limit that “it would not me notified by operator, but by monitoring systems, cables in Middle East wouldn’t be provided with auto-recloser, it is only for overhead lines up to MV level where most of faults are transient. We shall find “normal operating current” which is the full rating current “ for 220kV breakers 2500 AMPS” , breaking current capability, which is withstand capability for short circuit, it is 40 or 50 KA for 220KV network, and making current capability which is 2.55 times capability withstand, there were some papers talking about figures close to 3 times, mostly not applied because of higher cost, making current for 40KA is 100KA, for 50KA, it shall be 125KA.

Vacuum Circuit Breaker vs SF6 Circuit Breaker

Two kinds of circuit breakers commonly used in 10kV power distribution system In the electrical design of civil buildings, the following two circuit breakers are commonly used in 10kV systems. Vacuum interrupters are widely used in utility power transmission systems, power generation unit, and power-distribution systems for railways, arc furnace applications, and industrial plants. Sulfur hexafluoride circuit breakers protect electrical power stations and distribution systems by interrupting electric currents, when tripped by a protective relay. Instead of oil, air, or a vacuum, a sulfur hexafluoride circuit breaker uses sulfur hexafluoride (SF6) gas to cool and quench the arc on opening a circuit. Vacuum Circuit Breaker The contact of the vacuum circuit breaker, as Tavrida Electric , cuts off the circuit in the high vacuum arc extinguishing chamber, and the insulating medium and the arc extinguishing medium used are high vacuum air. There is basically no substance that can ...